Shenzhen Skoocom Electronic Co.,Ltd is one of the leading manufacturers and suppliers of SC1402LPV Micro Air Sampling Pump 3V 0.5L/min in China. We provide high quality products for medical devices and beauty appliance. Welcome to wholesale RoHS, REACH and ISO certified products made in China here and get quotation from our factory. Also, custom service and ODM service are available.
Home > Products > Air Pump > SC1402LPV
Micro Diaphragm Air Sampling Pump
SC1402LPV Micro Diaphragm Air Sampling Pump for Gas Detection
DC 3.0V | >0.5 L/min free flow | ≤ -30 mmHg vacuum | ø30 × 28.3 mm | <55 dB
SC1402LPV is a 30 mm micro diaphragm sampling pump that draws gas from a remote point to a sensor chamber or detector tube. It runs from a single 3.0V rail at under 200 mA, delivers more than 0.5 L/min of free flow, and holds up to -30 mmHg of vacuum, with two straight 2.5 mm ports marked INLET and OUTLET. Former model number: SC1220PM.

Voltage: DC 3.0V
Current: <200 mA
Free flow: >0.5 L/min
Rated vacuum: ≤ -30 mmHg
Noise: <55 dB at 30 cm
Body: ø30 × 28.3 mm
The practical consequence: if your tubing, filter, and sensor chamber together cost 20 mmHg, you still have roughly 0.3 L/min. If they cost 30 mmHg, you have about 0.1 L/min and your sensor response time will stretch accordingly.
Keep the sampling path short and wide, avoid unnecessary elbows and high-efficiency filters, and count every restriction in the budget. The rated vacuum of -30 mmHg is the ceiling for the whole circuit, not a per-component allowance.
Request a Sampling Pump Sample
Reading the Flow Curve Before You Specify
A sampling pump is chosen at the flow you need under your system's restriction, not at its free-flow figure. SC1402LPV moves about 0.6 L/min with the ports open, and the flow falls as vacuum builds at the inlet:
| Inlet vacuum | Approximate flow |
|---|---|
| 0 mmHg (free flow) | ≈0.6 L/min |
| -10 mmHg | ≈0.4 L/min |
| -20 mmHg | ≈0.3 L/min |
| -30 mmHg (rated) | ≈0.1 L/min |
Where SC1402LPV Fits in a Gas Detection System
Draws sample to the sensor instead of waiting for diffusion
A diffusion sensor only responds to gas that reaches it on its own. Adding SC1402LPV lets a portable instrument pull a sample from a confined space, a duct, or a remote probe, so the reading reflects the point you actually care about rather than the air around the instrument.
0.5 L/min matches common sensor sampling rates
Electrochemical and catalytic bead sensors are typically sampled in the 200–500 mL/min range. The free-flow figure of SC1402LPV sits inside that band, leaving headroom for normal tubing losses.
Two straight ports for inline installation
INLET and OUTLET are ø2.5 ± 0.10 mm barbs on a 14.0 ± 0.2 mm pitch, moulded in line with the body. The pump can be pushed straight onto 2–2.5 mm ID tubing without an elbow, which keeps both the footprint and the pressure loss low.
3V rail, under 200 mA
At 3.0V and below 200 mA, the pump draws under 0.6 W, so it can run from two alkaline cells or a single lithium cell through a small regulator, without a boost converter.
Quiet enough for handheld instruments
Rated below 55 dB at 30 cm, with the published curve sitting around 48–50 dB. The pump will not mask an alarm buzzer held at arm's length.
30 mm body for instruments built around millimetres
ø30 mm diameter and 28.3 ± 0.5 mm length, with two ø2.5 mm mounting holes on a 13.7 mm spacing. Small enough to sit beside the sensor stack rather than in a separate enclosure.
Duty Cycle: This Is an Intermittent Sampling Pump
The rated life is stated as more than 100 hours on the engineering drawing. That is a service-life figure, not a continuous-operation rating. Treated as run time, it corresponds to roughly four days of non-stop operation, about 100 days at one hour per day, or roughly 1.6 years at ten minutes per day.
SC1402LPV is therefore intended for portable detectors, spot checks, detector-tube sampling and sample-bag filling. For fixed installations that run a pump 24 hours a day, ask us for a continuous-duty model instead - specifying this pump for round-the-clock monitoring will consume its life in days.
Technical Specifications
| Model | SC1402LPV |
|---|---|
| Former model | SC1220PM |
| Pump type | Micro diaphragm air sampling pump, two-port flow-through |
| Rated voltage | DC 3.0V |
| Rated current | <200 mA |
| Air flow | >0.5 L/min (free flow) |
| Rated vacuum | ≤ -30 mmHg (≈ -4.0 kPa) |
| Noise | <55 dB at 30 cm |
| Medium | Air |
| Rated life | >100 hours (test condition to be confirmed) |
| Working environment | 0–50 °C, 75% RH |
| Body size | ø30 mm × 28.3 ± 0.5 mm |
| Ports | 2 × ø2.5 ± 0.10 mm, 14.0 ± 0.2 mm pitch, marked INLET / OUTLET |
| Mounting | 2 × ø2.5 mm holes, 13.7 mm spacing |
Values follow the SC1402LPV engineering drawing. Flow figures at intermediate vacuum levels are read from the published performance curve and should be confirmed against original test data for design release.
Design Checklist
- Add up your restriction first. Tubing length, bore, elbows, filters and chamber geometry all consume the 30 mmHg budget.
- Damp the pulsation. A diaphragm pump delivers pulsed flow. If your sensor is sensitive to flow transients, fit a small buffer volume between pump and sensor, or use a bypass bleed.
- Check media compatibility. The released medium is air. Acid gases, solvent vapours, and high humidity need a review of diaphragm and valve material before release.
- Confirm the duty cycle. Intermittent sampling only; ask about continuous-duty alternatives for fixed monitors.
- Do not assume ingress protection. No IP rating is published; house the pump where it stays dry.
- Check the label you will receive. Units may still carry the SC1220PM marking during the model transition. Both markings are the same pump.
- Plan for explosion-proof requirements separately. The pump is an electrical component; equipment intended for flammable atmospheres needs its own certification assessment.
Company introduction

Founded in 1998, Shenzhen Skoocom Electronic Co., Ltd. is a national high-tech enterprise with in-house R&D, precision manufacturing, and global marketing capabilities. In 2022 and 2025, it was awarded the title of National "Little Giant" Enterprise (Specialized, Refined, Unique, and Innovative) by the Ministry of Industry and Information Technology of China. Skoocom focuses on the R&D and production of various types of micro pumps, solenoid valves, and electromagnets, providing professional micro pump and valve solutions and related supporting technical services to enterprises in the fields of medical devices, AI smart home appliances (such as cleaning robots, learning, entertainment and lifestyle robots, 3D printers, smart toilets, kitchen appliances, coffee machines, water purifiers), maternal and child products, medical aesthetics and health, and laboratory research. The company is headquartered in Shenzhen, with manufacturing bases located in SongShan Lake Intelligent Valley, Dongguan, and Zhong'an Industrial City, Zhaoqing. We operate self-built manufacturing facilities spanning 50,000 ㎡, with a workforce of over 500 staff and multiple state-of-the-art production lines supporting an annual output of 50 million units.
Our factory & equipment




Our Certificate




Frequently Asked Questions
1. What flow can I expect at -20 mmHg?
Approximately 0.3 L/min, based on the published performance curve. At the rated -30 mmHg, the flow is around 0.1 L/min.
2. Can it run continuously in a fixed gas monitor?
The rated life is more than 100 hours, and the drawing does not specify continuous duty, so it suits portable and intermittent sampling. For round-the-clock fixed monitoring, ask us for a continuous-duty pump.
3. Does it deliver positive pressure as well as vacuum?
The pump is a two-port flow-through diaphragm design, so gas leaves the OUTLET port. The engineering drawing only specifies vacuum performance; contact us if you need a guaranteed positive-pressure figure.
4. Is it available in 6V or 12V?
SC1402LPV is a 3.0V pump. Other voltages in the sampling range are separate models - tell us your rail and we will point you to the right one rather than substituting.
5. What tubing fits the ports?
ø2.5 ± 0.10 mm barbs, suited to 2–2.5 mm inner-diameter flexible tubing.
6. Can it sample corrosive gases?
The released medium is air. Corrosive or solvent-laden gas requires a diaphragm and valve material review first.
7. Is it explosion-proof?
No explosion-proof certification is published for this pump. Instruments intended for flammable atmospheres require a separate certification assessment.
Send Your Sampling Path and Target Flow
Tell us the target flow at the sensor, tubing bore and length, filter type, required vacuum, duty cycle, and annual volume. We will confirm whether SC1402LPV holds your flow point, or point you to a higher-vacuum model.
Contact Skoocom EngineeringHot Tags: SC1402LPV Micro Air Sampling Pump 3V 0.5L/min manufacturers, suppliers, factory, customized, micro pneumatic pumps, Dc Water Pumps, High Pressure Electric Water Pump, pneumatic pumps, micro air pumps, Micro Diaphragm Air Pump