Shenzhen Skoocom Electronic Co.,Ltd is one of the leading manufacturers and suppliers of SC2710XPM Micro Diaphragm Air Pump 80kPa in China. We provide high quality products for medical devices and beauty appliance. Welcome to wholesale RoHS, REACH and ISO certified products made in China here and get quotation from our factory. Also, custom service and ODM service are available.
SC2710XPM Micro Diaphragm Air Pump for Beauty Devices and Air-Assisted Water Systems
A compact positive-pressure diaphragm pump for cosmetic instruments and small appliances. Free flow above 1.3 L/min, pressure above 80 kPa, noise under 62 dB, available in 3.0 V, 4.5 V, 6.0 V and 12.0 V windings. 27 mm pump head, 60.9 mm body, both ports on one end face.
- Free flow: >1.3 L/min
- Pressure: >80 kPa (≈600 mmHg)
- Noise: <62 dB at 30 cm
- Voltage: DC 3.0 / 4.5 / 6.0 / 12.0 V
- Life: 60,000 cycles (10 s on / 2 s off / 5 s exhaust)
- Leakage: <5 mmHg/min at 300 mmHg in a 500 cc tank


Where This Pump Fits
This is a positive-pressure pump. It pushes air out of the exhaust port at up to 80 kPa. It is not a vacuum source, and it is not sized to be the suction generator in a cleaning appliance.
| Application | Fit | Note |
|---|---|---|
| Beauty device spray / atomisation | Yes | 80 kPa is above typical nozzle range - plan a restrictor |
| Pneumatic massage / air cells | Yes | Intermittent duty suits the cycle rating |
| Air-over-liquid tank pressurisation | Yes, with caveat | See leakage note below |
| Continuous aroma diffusion | Not recommended | Cycle rating equals roughly 200 h of continuous running |
| Dust suction in a cleaning appliance | No | Flow is far below what suction needs |
Flow Against Pressure
The two headline numbers sit at opposite ends of one curve. Read the pair at your operating point.
| Outlet pressure | Flow (approx.) |
|---|---|
| 0 kPa | ~1.85 L/min |
| 20 kPa | ~1.42 L/min |
| 25 kPa | ~1.30 L/min |
| 40 kPa | ~0.95 L/min |
| 60 kPa | ~0.45 L/min |
| 80 kPa | ~0.05 L/min |
Above roughly 25 kPa the flow falls below the published 1.3 L/min figure. If your nozzle needs both high pressure and volume, size the nozzle first and let us confirm the operating point on a sample.
Specifications
| Parameter | DC 3.0 V | DC 4.5 V | DC 6.0 V | DC 12.0 V |
|---|---|---|---|---|
| Rated current | <800 mA | <600 mA | <450 mA | <300 mA |
| Free flow | >1.3 L/min | |||
| Pressure | >80 kPa | |||
| Inflation time | <15 s, 0 to 300 mmHg in a 500 cc tank | |||
| Leakage | <5 mmHg/min at 300 mmHg in a 500 cc tank | |||
| Noise | <62 dB at 30 cm | |||
| Medium | Air | |||
| Life test | 60,000 cycles (10 s on / 2 s off / 5 s exhaust) | |||
| Working environment | 0–50 °C ambient, 75 % RH | |||
| Pump head / motor | ø27.0 mm / ø24.3 mm, body 60.9 mm | |||
Air-Over-Liquid Systems: Read the Leakage Figure First
In an air-over-liquid design the pump pressurises a sealed water tank and a valve releases the liquid, so water never passes through the pump. Nothing clogs and nothing scales.
The constraint is leakage. At <5 mmHg/min in a 500 cc tank, a tank charged to 300 mmHg loses usable pressure in roughly an hour. A cleaning appliance runs for 60 to 120 minutes per session, so either the pump re-pressurises during the run, or the tank volume and seal quality have to absorb the loss. In a smaller tank the same leak rate produces a faster drop.
If your design relies on holding pressure for an entire cleaning cycle, tell us the cycle length and working volume, and we will test the assembly rather than quote the figure from a 500 cc bench.
Life and Duty
The rating is 60,000 cycles at 10 s on, 2 s off and 5 s exhaust. That is a cycle count, not an hours figure: 60,000 cycles equals about 167 hours of running time.
| Duty pattern | What 60,000 cycles covers |
|---|---|
| Continuous running | ≈200 hours (about 8 days) |
| 2 hours per day | ≈100 days |
| 5 actuations of 10 s per day | Many years |
This pump is specified for intermittent duty. For a continuously running appliance, tell us the daily hours before you specify it - a higher-cycle pump in the same family may be the better starting point.
Integration Notes
- Both ports on one end face. INLET and OUTLET are marked on the pump head; route tubing so the ports point down where possible for secure retention.
- Positive pressure only. Size the circuit expecting air out of the exhaust port. Do not design around a vacuum source unless you have confirmed the vacuum specification for your build.
- Restrictor for spray nozzles. 80 kPa is above the usual working range of fine-mist nozzles. A throttle or pressure regulator keeps droplet size stable.
- Voltage choice. 3.0 V and 4.5 V suit battery designs; 6.0 V and 12.0 V suit adapters. Confirm the winding when ordering - the four are not interchangeable.
- Intermittent duty. Do not run the pump continuously without confirming the thermal duty with us.
company introduction

Rooted in Fluid Control, Forging National Intelligent Manufacturing.
Over more than two decades of exploration and development, Skoocom has established four subsidiaries, each responsible for one of four key sectors: Product R&D, Precision Molding, Precision Rubber, and Liquid Silicone Rubber. This not only creates economies of scale but also continuously strengthens the foundation for Skoocom's growth and expansion by reducing costs, improving service quality, and enhancing innovation capabilities. The company has introduced a wide range of advanced equipment to ensure that every step-from raw materials to finished products-undergoes rigorous inspection, control, and testing, so that every product can meet the diverse application needs of different customers.
Our Certificate




Frequently Asked Questions
1. What is the pressure and flow of the SC2710XPM?
Above 80 kPa and above 1.3 L/min free flow. Those are the two ends of one curve - at 80 kPa the flow is close to zero, and the full 1.3 L/min is available only below roughly 25 kPa.
2. Can it be used for a breast pump?
Breast pumps need vacuum, not pressure. If your design calls for suction, this is the wrong part - ask us for the vacuum range you need and we will match a model.
3. Can it pressurise a water tank in a cleaning appliance?
Yes, in an air-over-liquid design where the pump never touches the water. Check the leakage figure against your cycle length: at <5 mmHg/min in 500 cc, a charged tank holds usable pressure for roughly an hour.
4. How long does the pump last?
60,000 cycles at 10 s on and 2 s off, which is about 167 hours of running. That is an intermittent-duty figure - continuous operation consumes it in roughly 200 hours.
5. Which voltage should I choose?
3.0 V and 4.5 V for battery-powered designs, 6.0 V and 12.0 V for adapter-powered ones. Current draw rises as voltage falls, so check your supply against the rated current for the winding you pick.
Send the Operating Point, Not Just the Application
Tell us: application; required pressure at the nozzle or tank; required flow at that pressure; supply voltage and available current; duty cycle and daily running hours; ambient and medium temperature; and whether the pump touches liquid. We will confirm the winding and the operating point, or tell you that a different model in the range is the better fit.
Request a Sample| Specification 产品规格 | |||
| 额定电压 Rated voltage | DC6.0V | DC12.0V | DC24.0V |
| 额定电流 Rated current | <450mA | <250mA | <200mA |
| 最大真空 Vacuum | <-400 mmHg | ||
| 最大压力 Pressure | >890 mmHg | ||
| 流量 Air flow | ≥2.8 L/min | ||
| 噪音 Noise | 65dB (30 cm away) | ||
| 使用流体 Apply for | Air | ||
| 寿命试验 Life test | 500 Hours | ||
| 使用环境 Environment | 0~50 ℃,75% RH | ||
Hot Tags: SC2710XPM Micro Diaphragm Air Pump 80kPa manufacturers, suppliers, factory, customized, Micro diaphragm electric pump, pneumatic pumps, Dc Water Pumps, Micro Diaphragm Air Pump, mini air pumps, Micro Water Pump Price